Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 45
Semi-rapid 35
Auxiliary 28
Other technical data
TOTAL POW‐
ER:
Gas original:
G30/G31 (3B/P) 30/30
mbar
771 g/h
Gas replace‐
ment:
G20 (2H) 20 mbar 11,0 kW
Electric supply: 220-240 V ~ 50/60 Hz
Appliance cate‐
gory:
II2H3B/P
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
Gas burners for LPG G30/G31 30/30 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Rapid 2,8 0,75 86 204
Semi-rapid 2,0 0,45 71 145
Auxiliary 1,0 0,33 50 73
Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
ENVIRONMENTAL CONCERNS
Recycle materials with the symbol . Put
the packaging in relevant containers to
recycle it. Help protect the environment
and human health by recycling waste of
15